ERP
Refrigerator Electronic Defrost Timer Universal UET240 Adjustable defrost frequency 4 to 12 hours, time 10 to 35 minutes ERUET240
ERUET240
Availability
Out of Stock
Part Number
ERUET240
MPN
ERUET240
Manufacturer
ERP
Compatible Brands:
Quality Parts
Easy to Install
Reliable
Long-Lasting
Frequently Bought Together






Refrigerator Electronic Defrost Timer — UET240
Universal ERP replacement defrost timer for compatible refrigerator and freezer applications. Match the complete appliance model, original timer, ratings, dimensions, and connections before ordering; universal is a catalog label, not a guarantee of fit.
Part details
- ERP part number: UET240
- Voltage/frequency: 240 VAC, 50/60 Hz
- Maximum inductive load: 1/2 HP
- Maximum resistive switching current: 5 A
- Contact arrangement: SPDT
- Adjustable defrost time: 10–35 minutes
- Adjustable defrost frequency: 4–12 hours
Symptoms this part may help address
- Refrigerator or freezer is not advancing through its defrost cycle
- Excessive frost or ice buildup associated with a failed timer
- Cooling is intermittent or the appliance runs warm after a defrost-control failure
These symptoms can also be caused by the thermostat, heater, sensor, wiring, control board, airflow, or sealed system. Diagnose the complete appliance before replacing a part.
Compatibility and installation
Confirm the exact appliance model, original part number, timer specifications, mounting, terminal layout, and wiring before purchase. Disconnect electrical power and follow the manufacturer’s service procedure. Electrical work should be performed by a qualified technician. Do not force a similar-looking part to fit or bypass a fuse, thermostat, interlock, or other safety device.
California Proposition 65 Warning: This product can expose you to chemicals known to the State of California to cause cancer and reproductive harm. For more information, visit www.P65Warnings.ca.gov.
- Installation guidance for UET240. This is a preparation checklist, not a model-specific service procedure. Confirm the appliance model, original part number, dimensions, connector arrangement and electrical ratings before installation. Obtain the manufacturer's instructions for that exact model. Before service, disconnect electrical power. Isolate water or gas supplies if the repair affects them. Electrical connections and any stored-energy components should be handled by a qualified technician. Follow the exact model instructions for access, removal, mounting and connections. Do not force a similar-looking part to fit, improvise wiring, or bypass a fuse, thermostat, interlock or other safety device. Reinstall guards and panels, and complete the manufacturer-specified safety and operating checks before returning the appliance to service. If the exact installation procedure or compatibility is uncertain, stop and contact the appliance manufacturer or a qualified service technician. Product/cross-reference information (not a service manual): https://supco.com/web/supco_live/products/UET240.html
UET240 ERUET240
- Refrigerator or freezer does not advance through defrost
- Excessive frost or ice buildup associated with a failed timer
- Cooling is intermittent or the appliance runs warm after a defrost-control failure
- Diagnose the thermostat, heater, sensor, wiring, control board, airflow, and sealed system before replacement.
Compatible models
Universal catalog label; no specific compatible brand or model fit is confirmed. Verify the complete appliance model, original timer, ratings, dimensions, connections, and terminal layout before ordering.
OEM & Generic Parts