{"product_id":"erp-replacement-wilbur-curtis-left-dump-valve-wc-889","title":"ERP ERWC-889 Coffee Maker Commercial Coffee Brewer Left Dump Valve For: Wilbur Curtis Wc 889 Wcwc | Replaces 3375000186, 889-101","description":"\u003ch2\u003eCommercial Coffee Brewer Left Dump Valve For: Wilbur Curtis WC-889, 3375000186, WCWC-889-101\u003c\/h2\u003e\u003cp\u003eERP WC-889 is an aftermarket replacement reference for the left dump valve used in compatible Wilbur Curtis commercial coffee brewers. It helps control the related brew-system water path when the original valve is leaking, stuck, or no longer operating correctly. This listing is supplied by ERP and is not represented as a genuine Wilbur Curtis-manufactured part. Verify the complete brewer model, valve orientation, tubing and connector arrangement, and original part number before ordering.\u003c\/p\u003e\u003ch3\u003eCompatible Part Numbers\u003c\/h3\u003e\u003cul\u003e \u003cli\u003eWC-889\u003c\/li\u003e \u003cli\u003e3375000186\u003c\/li\u003e \u003cli\u003eWC-818\u003c\/li\u003e \u003cli\u003eWC-889-101\u003c\/li\u003e \u003cli\u003eWCWC-818\u003c\/li\u003e \u003cli\u003eWCWC-889\u003c\/li\u003e \u003cli\u003eWCWC-889-101\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e \u003cli\u003e \u003cstrong\u003eDirect replacement reference:\u003c\/strong\u003e Replaces compatible Wilbur Curtis left dump valve applications.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eApplication:\u003c\/strong\u003e For compatible commercial coffee brewer water-system service.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003ePrimary part number:\u003c\/strong\u003e WC-889.\u003c\/li\u003e \u003cli\u003e \u003cstrong\u003eService benefit:\u003c\/strong\u003e Helps restore controlled water flow when the original valve is damaged or failing.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eFixes These Symptoms\u003c\/h3\u003e\u003cul\u003e \u003cli\u003eWater leakage from the left dump valve or its connections.\u003c\/li\u003e \u003cli\u003eValve remains open, closed, or operates intermittently.\u003c\/li\u003e \u003cli\u003eIncorrect or restricted water flow during brewer operation.\u003c\/li\u003e \u003cli\u003eVisible wear, cracking, corrosion, or failed valve testing.\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\u003cul\u003e\u003cli\u003eWilbur Curtis\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eCompatible Models\u003c\/h3\u003e\u003ch4\u003eAlpha Series\u003c\/h4\u003e\u003cul\u003e \u003cli\u003eALP1GT\u003c\/li\u003e \u003cli\u003eALP2GT\u003c\/li\u003e \u003cli\u003eALP2GTW\u003c\/li\u003e \u003cli\u003eALPHA-3GT\u003c\/li\u003e \u003cli\u003e1GT\u003c\/li\u003e \u003cli\u003e2GT\u003c\/li\u003e \u003cli\u003e3GT\u003c\/li\u003e \u003cli\u003e3GTL\u003c\/li\u003e \u003cli\u003e3GTR\u003c\/li\u003e \u003cli\u003e5GT\u003c\/li\u003e \u003cli\u003e5GTL\u003c\/li\u003e \u003cli\u003e5GTR\u003c\/li\u003e \u003cli\u003e6GT\u003c\/li\u003e \u003c\/ul\u003e\u003ch4\u003eAirpot and ThermoPro Series\u003c\/h4\u003e\u003cul\u003e \u003cli\u003eTLP10\u003c\/li\u003e \u003cli\u003eTLP15\u003c\/li\u003e \u003cli\u003eTLP20\u003c\/li\u003e \u003cli\u003eTLP61\u003c\/li\u003e \u003cli\u003eTCT\u003c\/li\u003e \u003cli\u003eTCTS10\u003c\/li\u003e \u003cli\u003eTCTS10600\u003c\/li\u003e \u003c\/ul\u003e\u003ch4\u003eDigital and GemX Series\u003c\/h4\u003e\u003cul\u003e \u003cli\u003eD500GT\u003c\/li\u003e \u003cli\u003eD1000GT\u003c\/li\u003e \u003cli\u003eD60GT\u003c\/li\u003e \u003cli\u003eD60GT61A412\u003c\/li\u003e \u003cli\u003eGEM-12\u003c\/li\u003e \u003cli\u003eGEM-12-10\u003c\/li\u003e \u003cli\u003eSCD500GT62A000\u003c\/li\u003e \u003cli\u003eSCD1000GT13A009\u003c\/li\u003e \u003c\/ul\u003e\u003ch4\u003eCombo and Other Commercial Brewers\u003c\/h4\u003e\u003cul\u003e \u003cli\u003eC500AP\u003c\/li\u003e \u003cli\u003eCBP\u003c\/li\u003e \u003cli\u003eCBS\u003c\/li\u003e \u003cli\u003eCGC\u003c\/li\u003e \u003c\/ul\u003e\u003ch3\u003eInstallation and Safety\u003c\/h3\u003e\u003cp\u003eDisconnect electrical power, shut off the water supply, and allow the brewer to cool before service. Relieve water pressure, document tubing and connector locations, and compare the replacement valve with the original before removal. Install the valve in the original orientation, secure all tubing and electrical connections, restore water pressure slowly, and inspect every connection for leaks before returning the brewer to service. Commercial brewer repairs should be completed by a qualified technician.\u003c\/p\u003e\u003ch3\u003eDisclosure\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e Cancer and Reproductive Harm - http:\/\/www.P65Warnings.ca.gov\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAlways verify the complete brewer model, original valve part number, valve orientation, tubing, connectors, and mounting arrangement before ordering.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ERP","offers":[{"title":"Default Title","offer_id":50280528969971,"sku":"ERWC-889","price":42.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/7859\/2755\/files\/wc-889top_521f289b-f661-42de-8b4a-f86cd0ef85f3.png?v=1787805843","url":"https:\/\/authenticapplianceparts.com\/products\/erp-replacement-wilbur-curtis-left-dump-valve-wc-889","provider":"Authentic Appliance Parts","version":"1.0","type":"link"}