{"product_id":"dryer-thermal-fuse-for-whirlpool-wp3392519-set401-3392519-er3392519","title":"Dryer Thermal Fuse Replacement For: Whirlpool \/ Kenmore WP3392519 3392519 3388651 ET401 SET401","description":"\u003ch2\u003eDryer Thermal Fuse Replacement For: Whirlpool \/ Kenmore WP3392519 3392519 3388651 ET401 SET401\u003c\/h2\u003e\u003cp\u003eHelp restore the dryer's overheat protection with this ERP replacement thermal fuse. This one-time fuse opens to interrupt the motor circuit when the dryer reaches an unsafe temperature, so a failed fuse can cause a no-start, no-heat, or interrupted-cycle condition. This is a direct replacement for the listed references when the temperature rating, terminals, and mounting match. Check airflow and the complete appliance model before ordering.\u003c\/p\u003e\u003ch3\u003eCompatible Part Numbers\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eER3392519\u003c\/li\u003e\n\u003cli\u003eWP3392519\u003c\/li\u003e\n\u003cli\u003eAP6008325\u003c\/li\u003e\n\u003cli\u003e3392519\u003c\/li\u003e\n\u003cli\u003e3388651\u003c\/li\u003e\n\u003cli\u003e694511\u003c\/li\u003e\n\u003cli\u003e80005\u003c\/li\u003e\n\u003cli\u003eET401\u003c\/li\u003e\n\u003cli\u003eSET401\u003c\/li\u003e\n\u003cli\u003ePS11741460\u003c\/li\u003e\n\u003cli\u003eWP3392519VP\u003c\/li\u003e\n\u003cli\u003eB071ZPDCVY\u003c\/li\u003e\n\u003cli\u003eB00MZH0R4U\u003c\/li\u003e\n\u003cli\u003eB00PDXA2CA\u003c\/li\u003e\n\u003cli\u003eB0081EATSK\u003c\/li\u003e\n\u003cli\u003eB011BWTX0S\u003c\/li\u003e\n\u003cli\u003eB015YW8DJS\u003c\/li\u003e\n\u003cli\u003eB008DK2NOK\u003c\/li\u003e\n\u003cli\u003eB011OBNJLK\u003c\/li\u003e\n\u003cli\u003eB00MZH0RZ4\u003c\/li\u003e\n\u003cli\u003eB00IQ9VQL4\u003c\/li\u003e\n\u003cli\u003eB011OBMGF0\u003c\/li\u003e\n\u003cli\u003eB011OBN0X2\u003c\/li\u003e\n\u003cli\u003eB00MZH0OPC\u003c\/li\u003e\n\u003cli\u003eB00QMHDWUU\u003c\/li\u003e\n\u003cli\u003eB00PDXA0KE\u003c\/li\u003e\n\u003cli\u003eB0156N9Q1O\u003c\/li\u003e\n\u003cli\u003eB000NCTOUM\u003c\/li\u003e\n\u003cli\u003eB011BWTQ82\u003c\/li\u003e\n\u003cli\u003eB00MZH0RK4\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatible Models\u003c\/h3\u003e\u003cp\u003eFits various models. Please verify compatibility with us before ordering\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect replacement:\u003c\/strong\u003e Replaces the listed thermal fuse references for compatible Whirlpool and Kenmore dryers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary function:\u003c\/strong\u003e Interrupts the dryer motor circuit when the appliance reaches the fuse's approximately 91°C \/ 196°F limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey benefit:\u003c\/strong\u003e Restores one-time overheat protection after the underlying airflow or heating fault has been diagnosed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation ease:\u003c\/strong\u003e Uses two 3\/16-inch terminals and mounts on the blower wheel housing when the model and mounting match.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFixes These Symptoms\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDryer will not start or will not tumble\u003c\/li\u003e\n\u003cli\u003eNo heat or not enough heat\u003c\/li\u003e\n\u003cli\u003eDryer gets too hot or shuts down during a cycle\u003c\/li\u003e\n\u003cli\u003eTimer will not advance or drying takes too long\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWhirlpool\u003c\/li\u003e\n\u003cli\u003eKenmore\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProduct Details\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSKU:\u003c\/strong\u003e ER3392519\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary part number:\u003c\/strong\u003e 3392519\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart type:\u003c\/strong\u003e Dryer thermal fuse\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecifications:\u003c\/strong\u003e Approximately 91°C \/ 196°F, two 3\/16-inch terminals, non-resettable\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAlways verify your model number before ordering.\u003c\/strong\u003e Check the label inside the dryer to confirm compatibility.\u003c\/p\u003e\u003cp\u003eDisconnect power and verify the appliance is de-energized. Locate the fuse on the blower wheel cover or housing as specified by the model service manual. Test for continuity before replacement, and replace the fuse if it is open. Never bypass or reset a one-time fuse. Check clogged vents and restricted airflow before returning the dryer to service, then reinstall all guards and complete a controlled test.\u003c\/p\u003e\u003cp\u003eNeed a matching cleaning product? \u003ca href=\"https:\/\/authenticapplianceparts.com\/search?q=affresh\u0026amp;type=product\"\u003eShop affresh products\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eERP aftermarket replacement; not represented as manufactured by the original appliance maker. Brand names and original part numbers are used for identification.\u003c\/p\u003e\u003cp\u003eProp 65 Warning: Cancer and Reproductive Harm – www.P65Warnings.ca.gov\u003c\/p\u003e","brand":"ERP","offers":[{"title":"Default Title","offer_id":50274716025075,"sku":"ER3392519","price":2.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0774\/7859\/2755\/files\/57_e4dcaa73-2185-4225-8606-446f4f65d574.jpg?v=1786586515","url":"https:\/\/authenticapplianceparts.com\/products\/dryer-thermal-fuse-for-whirlpool-wp3392519-set401-3392519-er3392519","provider":"Authentic Appliance Parts","version":"1.0","type":"link"}